Standard
Mounting
Voltage
Enclosure
Motor type
Description
NEMA
Horizontal
LV
TEFC
AEGA
AEGE EPACT
ODP
ASGA  
ASGANE  
Vertical
TEFC
AETA  
AETE EPACT
IEC, BS, AS, JIS, JEC, CNS Horizontal AEGF
AEGL  
ODP
ASGF  
Vertical
TEFC
AETF  
AETL  
Features:
¡´Light weight
¡´Multiple mountings
¡´Large stocks




Type Code: AEGA / AETA TOP
  Low Voltage Rolled Steel Frame Motors, Design B

Output 1/3 ~ 2HP
Pole (Speed) 2 ~ 6
Voltage 230/460V (usable on 208V at 1.0 SF)
Frequency (Hz) 60
Frame Size A56C ~ C56C
Protection Enclosure TEFC, IP 44

Design Standards: NEMA MG-1, MG-13
Stator insulation: Class F Insulation, B rise SF 1.15.
Test procedure: ANSI/IEEE-112 Method B and full voltage measuring starting performance.

 

Type Code: ASGA TOP
  Low Voltage Rolled Steel Frame Motorse

Output 1/3 ~ 3HP
Pole (Speed) 2 ~ 6
Voltage 230/460V
Frequency (Hz) 60
Frame Size A56~B56
Protection Enclosure IP 22 Open, Drip-Proof

Design Standards: NEMA MG-1, MG-13
Environment: non-hazardous
Stator insulation: Class F Insulation, B rise SF 1.15

 

Type Code: AEGF TOP
  Low Voltage Rolled Steel Frame Motors

Output 1/4 ~ 3 HP
Pole (Speed) 2 ~ 6
Voltage 200 ~460
Frequency (Hz) 50, 60
Frame Size 63 ~ 90
Protection Enclosure IP 44

 

Type Code: AETF TOP
  Low Voltage Rolled Steel Frame Motors

Output 1/4 ~ 3 HP
Pole (Speed) 2 ~ 6
Voltage 200 ~460
Frequency (Hz) 50, 60
Frame Size 63 ~ 90L
Protection Enclosure IP 44

 

Type Code: ASGANE TOP
  Low Voltage Rolled Steel Frame Motors EPACT

Output 1-1/2 ~ 40HP
Pole (Speed) 2 ~ 6
Voltage 230/460V
Frequency (Hz) 60
Frame Size 143T~286TS
Protection Enclosure IP 22 Open, Drip-Proof

Design Standards: NEMA MG-1, MG-13
Environment: non-hazardous
Stator insulation: Class F Insulation, 80¢Jrise at SF 1.15

 

 

Type Code: AEGE /AETE TOP
  Low Voltage Rolled Steel Frame Motors EPACT, Design B

Output 1 ~ 2HP
Pole (Speed) 2 ~ 6
Voltage 230/460V (usable on 208V at 1.0 SF)
Frequency (Hz) 60
Frame Size 143C ~ 145C
Protection Enclosure TEFC, IP 44

Design Standards: NEMA MG-1, MG-13
Stator insulation: Class F Insulation, B rise SF 1.15.
Test procedure: ANSI/IEEE-112 Method B and full voltage measuring starting performance.

 

Type Code: AEGL TOP
  Standard 3-Phase High Efficiency Induction Motors
Low Voltage Rolled Steel Frame Motors

Output 1/2 ~ 2 HP
Pole (Speed) 2 ~ 6
Voltage 200 ~460
Frequency (Hz) 60
Frame Size 71 ~ 90
Protection Enclosure IP 44

 

Type Code: AETL TOP
  Standard 3-Phase High Efficiency Induction Motors
Low Voltage Rolled Steel Frame Motors

Output 1/2 ~ 2 HP
Pole (Speed) 2 ~ 6
Voltage 200 ~460
Frequency (Hz) 60
Frame Size 71 ~ 90
Protection Enclosure IP 44


 

Type Code: ASGF TOP
  Low Voltage Rolled Steel Frame Motors

Output 1/2 ~ 3 HP
Pole (Speed) 2 ~ 6
Voltage 200 ~460
Frequency (Hz) 50, 60
Frame Size 80 ~ 90L
Protection Enclosure IP 22

 

 

 

 

 

 

 

 

 

 

 

 

 


 

Copyright©2007 TECO Electric & Machinery Co.,Ltd. All Rights Reserved.